Squareyards Logo
Blogs
Sell or Rent Property
Login
Rera Banner
residential New Launch Source: rera.tg

West Peak Treelyn RERA Details - P02400010387, Hyderabad

View the RERA registration, promoter, approval, building, inventory, document and construction-progress disclosures for West Peak Treelyn under registration P02400010387 in Hyderabad, Telangana. Data is sourced from rera.tg.

RERA

RERA Snapshot

The most important statutory project disclosures, generated dynamically from available RERA fields.

  • RERA Number P02400010387
  • Project Name TREELYN
  • Project Type Residential
  • Project Status New Launch
  • Original Completion 10 September 2028
  • Documents 19 Verified
Timeline

Project Timeline & Completion Details

Key statutory dates from registration through proposed completion and permit validity.

Proposed Start 10 September 2025 Expected commencement of civil works and foundation on site.
Original Completion 10 September 2028 Mandated date for project handover to the allottees and final compliance filing.
Promoter

Promoter, Organisation & Member Details

Declared promoter entity, address and corporate identifiers on file with the authority.

Organisation Type Partnership
Individule Name West Peak Builders
GST Number 36AAFFW0441E1ZH

Promoters, Co-promoters & Members

NameRole
Rajashekar Rao BAuthorized Signatory
Yugander Reddy MPartner
Sai Kumar KPartner

Understand this Project's RERA details

Get clear answers and additional support from our RERA experts.

RERA Banner
Buildings

Buildings, Towers & Building-Level Details

Statutory building-level disclosures including tower height, sanctioned floors, structural counts and parking areas.

Building Detail
Project Name Name Date of Completion No. of Slab No. of Slits Total Parking Area
TREELYN TREELYN 2028-09-10 5 1 16

Scroll horizontally to view all building-level fields. Values marked "-" were not disclosed in the source RERA record.

Inventory

Unit Inventory & Configuration Details

Configuration mix and floor-level disclosures with both grouped and raw RERA views.

Total Units 45
Configurations 2
Inventory Type RESIDENTIAL
Configuration Distribution
Three Bedroom 15 units · avg area 176.97 Sq.mt.
Two Bedroom 30 units · avg area 123.28 Sq.mt.
  • TREELYN
Floor-Wise Inventory Explorer
Floor Apartment Type Carpet Area Mortgage Area No. of Apartment No. of Booked Apartment
GF Three Bedroom 174.97 False 3 0
GF Two Bedroom 124.49 True 3 0
GF Two Bedroom 122.07 True 3 0
1 Three Bedroom 174.97 False 3 0
1 Two Bedroom 124.49 False 3 0
1 Two Bedroom 122.07 False 3 0
2 Three Bedroom 174.97 False 3 0
2 Two Bedroom 124.49 False 3 0
2 Two Bedroom 122.07 False 3 0
3 Three Bedroom 179.97 False 3 0
3 Two Bedroom 124.49 False 3 0
3 Two Bedroom 122.07 False 3 0
4 Three Bedroom 179.97 False 3 0
4 Two Bedroom 124.49 False 3 0
4 Two Bedroom 122.07 False 3 0
Parking

Parking, Garage & Area Details

Parking provision declared in the sanctioned plan.

Type Proposed Booked Work Done
Covered Parking 16 0 -
Open Parking 0 0 -
Development

Development Works & Common Area Disclosures

Project-level common infrastructure disclosures as reported by the developer to the RERA authority.

Internal Roads Footpaths % not reported Water Supply % not reported Sewerage % not reported
Storm Water Drains % not reported Green Strip % not reported Street Lighting % not reported
Community Buildings % not reported Treatment And Disposal Of Sewage Sullage Water % not reported Solid Waste Management Disposal % not reported
Water Conservation Rainwater Harvesting % not reported Energy Management % not reported Fire Protection And Fire Safety Requirements % not reported
Electrical Meter Room Substation Receivingstation % not reported Aggregate Area Of Recreational Open Space % not reported
Activity

Building Activity Progress

Statutory activity-wise construction progress as declared by the developer, per building/tower.

  • TREELYN
TREELYN · Overall Progress 0%
Excavation
Not Started
% Work0%
X number of Basement(s) and Plinth
Not Started
% Work0%
X number of Podiums
Not Started
% Work0%
Stilt Floor
Not Started
% Work0%
X number of Slabs of Super Structure
Not Started
% Work0%
Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises
Not Started
% Work0%
Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises
Not Started
% Work0%
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.
Not Started
% Work0%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing
Not Started
% Work0%
Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate
Not Started
% Work0%
Documents

RERA Documents & Filings

All statutory documents uploaded by the promoter to the authority portal.

Tg Details Html
Tg Certificate Pdf
Copy Of The Legal Title Report
Copy Of The Legal Title Report
Details Of Encumbrances
Copy Of Approval Layout Plan
Agreement Of Sale (AOS) [As Per The Format]
Declaration In FORM B
Commencement Certificate/Copy Of Building Permit/Proceedings
Copy Of Sanctioned Building Plan
Status Of Formation Of Legal Entity (Society/Co Op Etc.)
Copy Of Board Resolution For Appointment Of Authorized Signatory In Case Of Other Than Individual
Mortgage Deed
Allotment Letter [As Per The Format]
Copy Of The Legal Title Report
Details Of Encumbrances
Agreement Of Sale (AOS) [As Per The Format]
Declaration In FORM B
Allotment Letter [As Per The Format]
Country/City